Load Miser Energy Divider Controller

Model #D-LM

IDEAL FOR COST AND ENERGY SAVINGS, OR WHEN SYSTEM CAPACITY IS LIMITED SUCH AS THE ADDITION OF A HOT TUB/ELECTRIC VEHICLE CHARGER TO EXISTING RESIDENCE SERVICE.

  • EEMAC 3R enclosure

  • Specifically designed as a load saving device, to be used where non-essential load is connected to an essential load circuit.

  • Load saver cuts off power to the non-essential circuit only. Reducing load saves service upgrades.

  • Adjustable 5 to 50 Amp of the circuit upstream rating.

  • Easy to install for new and existing installations, simply connect in series of the existing load.

  • Optional time of day clock prevents non-essential load from operation on/off hour, increasing energy savings and allowing non-essential load to operate on/off time energy availability.

  • Sensing has adjustable 5 to 50 second time delay action to prevent rapid load cycling. Sensing is on only L1. To avoid nuisance tripping if loads are unbalanced add second phase current sensor option.

  • CSA certified assembly

Options

  • Ground fault load breaker class ‘A’ 5mA 􀀀

  • Large capacity control to 600A, 600V 􀀀

  • Dual line sensing - recommended when unbalanced loads could be encountered 􀀀

  • Time clock for interval operation of load contactor eg. time of day 􀀀